TM 10-5410-224-14
REPAIR OF FOLDOUT FLOOR PANELS
(a) Remove rivets (11) to detach seal strip
(12).
The description of the foldout floor panels is
NOTE
7-2. Removal.
replacement procedure.
Most foldout floor panel repair can be ac-
(b) Remove and replace seal (8 or 13) in
complished without removing the panel from the
shelter. Therefore, do not remove the foldout floor
panels unless it is absolutely necessary.
(c) Re-attach seal strip (12) usig rivets (11).
7-3. Cleaning
(2) Removal and replacement of hinge
Use a clean, soft bristle brush to remove dust,
assembly (5), proceed as follows:
dirt, and lint from all parts and surfaces of the
(a) Remove four rivets (4) to detach hinge
foldout floor panels. Wash floors by scrubbing
assembly (5).
with soap, clean water, and a mop.
(b) Replace hinge assembly (5) by securing
7-4. Inspection and Repair.
to foldout floor panel (17) using four rivets (4).
a. Inspection. Inspection of the foldout floor
(3) Removal and replacement of strike (fig. 4-
panels is accomplished by performing the following
5). To
remove and replace strike (10), proceed as
procedure:
follows:
(1) Perform inspection procedure of paragraph
(a) Remove two rivets (9) to detach strike
(10).
(2) Check strikes for security of attachment.
NOTE
b. Repair. If a foldout floor panel has minor
structural damage, repair the panel in accordance
replacement procedure.
(b) Replace strike (10) by securing to
has major damage, replace the entire panel making
foldout floor panel (17) using two rivets (9).
sure that the new panels meets the requirements
7-5. Installation.
of Brunswick drawings. If a part attached to a
If entire foldout floor panel is to be replaced,
foldout floor panel is damaged, remove and replace
refer to the installation procedure contained in
the damaged parts as follows:
To remove and replace seals (8 and 13), proceed as
follows: