TM 10-5410-221-24
1
Screw (4)
18
Seal
35
Bracket, receptacle mounting
2
Washer (4)
19
Seal
36
Bolt (8)
8
Cover assembly
20
Seal
37
Washer (8)
4
Rivet (10)
21
Pin
38
Bracket, receptacle mounting
6
Hinge
22
Fastener stud
39
Rivet (2)
6
Seal
23
Rivet (8)
40
Receptacle
7
Seal
24
Cover assembly
41
Rivet (20)
8
Seal
25
Rivet (9)
42
Nut plate (10)
9
Rivet (5)
26
Hinge
43
Insulation
10
Door assembly
27
Pin (2)
44
Bolt (5)
11
Seal
28
Fastener stud (2)
45
Washer (5)
12
Seal
29
Rivet (4)
46
Bracket, disconnect mounting
13
Seal
30
Receptacle (2)
47
Bolt (4)
14
Seal
31
Seal
48
Washer (4)
15
Rivet (8)
32
Insulation
49
Bracket, pump mounting
16
Door assembly
33
Bolt (8)
50
Rivet (29)
17
Seal
34
Washer (8)
51
Water box assembly
Figure 10-10-Continued
e. Overhaul. Overhaul the water box fixed end
(2) Remove hinge pins from hinge halves and
panel assembly as required to return to 2 serviceable
f. Assembly. Assemble the folding roof panel in
Note. Block up folding portion of shelter after
removal from fixed portion to prevent any possible
guide and observing the following.
damage to panel assemblies.
c. Disassembly. Disassemble the fixed floor
panel assembly as required to replace damaged part
(Located in back of manual)
according to sequence of index numbers assigned to
(1) Cement seals using procedures outlined
(1) Remove cover assembly (3) by removing
(2) Cement receptacle boxes in position using
bolt (1) and washers (2). Remove hinge (5) from cover
(3) by removing rivets (4). Remove gasket (6, 7, 8) from
g. Installation. Install the water box fixed end
cover assembly (3) by peeling from cemented area per
guide.
stud (10) from cover assembly (3).
(2) Remove bolt (11) and washer (12) to
Fixed Floor Panel Assembly
remove bulkhead assembly (13, 14). Separate bulkhead
(13) from bulkhead (14) by removing screw (17).
Remove seal (15) from bulkhead assemblies (13, 14).
a General. The fixed floor panel assembly is a
(3) Remove screws (16, 17) and remove
metal faced honeycomb core panel housing the shelter
water tunnel cover assemblies (18, 19, 20, 21, 22).
water tunnel and electrical raceway.
It provides
(4) Remove screws (23) and remove
electrical raceway cover assembly (24). Remove rivnut
b. Removal.
Remove the fixed floor panel
(25) by drilling out using a drill bit having the same
assembly as required to replace damaged parts as
diameter as the rivnut.
follows.
(5) Remove towing bracket (28) by removing
(1) Remove fixed end panels, fixed roof
screws (26) and washers (27). Remove
panels and water box assembly according to procedures
.