TM 10-5411-201-14T.O. 35E4-178-14-9.(cont)8.Connect three wires from electrical cord (9) to three wires fromlamp holder (2) as follows:FromToElectricalCordLampHolderBlack WireBlack WireWhite WireWhite WireGreen WireBare Wire9.Secure these wires with three wire nuts (8).10.Make sure connected wires are positioned in opening at top ofexterior light post (10) and assemble gasket (7) and outlet cover(6) to top of exterior light post (10) with two captive screws (5).11.Install flood light (1) in lamp holder (2).4-10.INCANDESCENT LIGHT ASSEMBLY TESTING, REPLACEMENT AND REPAIRThis task covers.a.Testingd.Repairb.Removale.Installationc.Cleaning, InspectionINITIALSETUPStandardToolsPersonnelGeneral mechanics tool kitElectricianTestEquipmentMultimeter, Appendix B, Item 4WARNINGThis fixturedangerous ifincandescentcircuit brcontains voltage that iscontacted.Before replacinglight assembly, set alleakers and switches to OFF Position.TESTING1.Set all circuit breakersand switches to OFF position.2.Remove two screws (1) andcover (2).3.Unscrew bulb (3) from lightfixture (4).4-21