TM 10-5411-201-14
T.O. 35E4-178-1
4-8.
(cont)
REPAIR
Replace damaged receptacles, binding post, terminals, or threaded stud.
INSTALLATION
Terminals/Connectors
1.
Install threaded stud (28), terminal lug (27), three washers (26),
three lockwashers (25), and four nuts (24) in panel (5).
2.
Install binding post body (33), nylon washer (32), two O-rings (31),
nylon washer (30), brass washer (29), lockwasher (23), nut (22), and
rubber cap (21) in panel (5).
3.
Connect all wires to terminals/connectors at rear of panel (5).
(Refer to paragraph 4-47)
4.
Inside shelter, position cover assembly (4) against personnel door
end endwall panel and secure with washers (3), lockwashers (2), and
screws (l).
Receptacles
5.
Install receptacles (17 and 18), nuts (16), washers (19), receptacle
covers (15), lockwashers (14), and screws (13) in panel (5).
6.
Install gaskets (12), receptacles (10 and 11), nuts (9), receptacle
covers (8), lockwashers (7), and screws (6) in panel (5).
7.
Connect all wires (20) to receptacles (10, 11, 17, and 18).
(Refer
to paragraph 4-47)
8.
Inside shelter, position cover assembly (4) against personnel door
end endwall panel and secure with washers (3), lockwashers (2), and
screws (1).
4-17