TM 10-5411-200-14
T.O. 35E4-177-1
3-2.
(cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
6.
7.
8.
9.
Step 3.
Check visually for burned out fluorescent lamps.
a.
Unplug flexible cable connector and replace
lamp.
(Refer to paragraph 3-5.)
b.
Reconnect flexible cable connector.
ONE OR MORE FIXED ROOF AREA CEILING LIGHTS FAIL TO COME ON.
Check visually for burned out fluorescent lamps.
a.
Turn off appropriate circuit breaker and replace
lamp.
(Refer to paragraph 4-12.)
b.
Turn on appropriate circuit breaker.
NO POWER AT ONE OR MORE INTERIOR UTILITY OUTLETS.
Check and reset associated circuit breakers.
Notify organizational maintenance.
NO POWER AT ONE OR BOTH EXTERIOR UTILITY OUTLETS.
Check and reset circuit breaker.
Notify organizational maintenance.
AREA LIGHT FAILS TO COME ON.
Step 1.
Check and reset circuit breaker.
Step 2.
Check visually for burned out bulb.
Change bulb.
Notify organizational maintenance.
NO POWER AT HEATER/AC SUPPLY.
Step 1.
Check that outside power is properly connected to service
entrance connector on power entry panel, and check general
condition of cable and connectors.
a.
Make proper power connection.
b.
Check for defective cable or connectors.
Step 2.
Check and reset circuit breakers.
Notify organizational maintenance,
3-3