TM 10-5411-200-14
T.O. 35E4-177-1
3-4.
(cont)
INSTALLATION
1.
Position post of area light assembly (3) in two brackets (4) on
shelter and tighten two wingnuts (2) to secure light to shelter.
2.
Connect area light assembly connector (1) to power entry panel.
3.
Place circuit breaker CB8 to on position.
3-5.
HINGED ROOF AREA CEILING LIGHT REPLACEMENT
This tasks covers:
a. Removal
b.
Installation
W A R N I N G
This fixture contains voltage that is dangerous
if contacted.
Before replacing hinged roof area
ceiling light, make sure that electrical power is
completely disconnected from circuit involved.
REMOVAL
1.
Place ceiling light switch and circuit breaker CB6 to off position.
2.
Unplug cable connector (1) from receptacle outlet (twist-lock type
connector) .
3.
Retract plunger (2) and slide hinged roof area ceiling light (3)
toward cable end to disengage two brackets (4) from four captive
Studs
INSTALLATION
1.
Place
holes
2.
Slide
(5) in hinged roof.
hinged roof area ceiling light (3) against hinged roof with
in two brackets (4) over four captive studs (5).
light away from cable end to engage two brackets (4) on four
captive studs (5).
3.
Plug cable connector (1) in receptacle outlet.
3-5