TM 9-2330-275-14&P4-53. TOOLBOX AND PLATFORM MAINTENANCE (M832 SN J089-001 THRU 159 ANDJ017-160 THRU 350 ONLY) (Con’t).6.7.8.9.10.Remove six screws (18) and nuts (21), two catch strikes (20), andfour shims (19) from cover assembly (9).WARNINGDry cleaning solvent, P-D-880, is toxicand flammable. Always wear protectivegoggles and gloves, and use only in awell-ventilatad area. Avoid contact withskin, eyes, and clothes, and DO NOTbreathe vapors.DO NOT use nearopen flame or excesssive heat. Thesolvent’s flash point is 100°F-138°F(38°-59°C). If you become dizzy whileusing drycleaning solvent, Immediatelyget fresh air and medical help. If solventcontacts your eyes, immediately washthem and get medical aid.Remove two screws (24) and self-locking nuts (16) and eye bracket (25) from cover assembly (9).self-locking nuts.Remove four nuts (17) and screws (22) and cover (23) from cover assembly(9).Remove seal (43) from groove in platform assembly (11). Use dry cleaning solvent to remove anyDiscard seal.Remove toolbox prop (26) from two eyebolts (27).Discardresidue.4-138