TM 10-5411-235-13
DIRECT SUPPORT TROUBLESHOOTING
0027 00
Table 1. Direct Support Troubleshooting Procedures
INITIAL SETUP:
Maintenance Level
Materials/Parts
Direct Support
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
27.1
Dents or Punctures on
1. Inspect shelter and door 1. Repair dents and Repair
Shelter
Exterior
or
interior and exterior for
Interior
dents and punctures
2.
Inspect panel surfaces for
2. Repair Delaminations. See 0033
delamination
3. Inspect drip molding above
3. Replace drip molding. See 0035
top of door exterior for
damage
27.2
Drain Plug Not Sealing
1. Inspect for presence of drain
1. If missing or fails to fit tight in
Properly
plug and secure fit in drain
drain tube, replace drain plug.
tube
1. If difficult to move to upright
27.3
Difficulty Accessing
1. Inspect Handhold Assembly
position, lubricate in accordance
Shelter Roof from
for damage or improper
Steps.
operation
27.4
Lifting Ring Contact
1. Inspect lifting ring bumpers
1. Repair lifting rings. See 0034 00
Shelter Wall
for damage or missing areas
27.5
Door Assembly Binds
1. Test door operation open 1. If door does not operate
and close door several
smoothly,
lubricate
in
times.
accordance with Lubrication
2. Inspect door for loose or
missing
hardware
or 2. If a hinge is damaged, notify
damaged hinge
your supervisor
27.6 Door Assembly Does Not
1. Check RFI/EMI gasket for
1. Replace RFI/EMI gasket.
See
Seal Securely
damage.
2. Replace RFI/EMI gasket
2. If door still does not close tightly,
notify your supervisor
END OF WORK PACKAGE
0027 00-2