TM 10-5410-224-14
REPAIR OF CENTER STRUCTURE FLOOR PANEL
6. Repair. If the center structure floor panel has
minor structural damage, repair the panel in ac-
The description of the center structure floor
If a part attached to the center structure floor
11-2. Cleaning.
panel is damaged, remove and replace the damaged
Use a clean, soft bristle brush to remove dust,
part as follows:
dirt, and lint from all parts and surfaces of the
NOTE
floor panels. Wash floors by scrubbing with soap,
For removal and replacement of inserts, follow
clean water, and a mop.
11-3. Inspection and Repair.
(1) Removal and replacement of dolly adapter
a. Inspection. Inspection of the center structure
floor panel is accomplished by performing the
adapter bracket (16), proceed as follows:
following procedure:
(a) Remove six screws (14) and washers (15)
(1) Perform inspection procedure of paragraph
and five screws (11 ), washers (12) and nuts (13) to
detach dolly adapter bracket (16).
(2) Check time guide assemblies for damage.
(b) Replace dolly adapter bracket (16) by
(3) Check floor skids and support plates for
securing to center structure floor panel using five
security of attachment and general condition.
screws (11), washers (12), and nuts (13), and six
(4) Check dolly brackets and support angles
screws (14) and washers (15).
for damage.
11-1