TM 9-2330-390-14&P4-46.SIGNAL CONDITIONING BOX-TO-FORWARD JUNCTION BOX CABLE ASSEMBLYREPLACEMENT (Con’t).14.Close cover (4) of forward junction box (6) andtighten three screws (1).13.Install seven cable assembly wires (2) on posi-tions 1 through 6 and 8 of terminal block (8) withscrews (9).12.Install green ground wire (3) on top right screw (5)with nut (7).Follow-on Tasks:• Connect intradolly cable to forward junction box and rear junction box (see paragraph 2-11).• Connect intervehicular cable to signal conditioning box and towing vehicle (see paragraph 2-11).• Check operation of lights.4-88