TM 9-2330-390-14&P
4-46.
SIGNAL CONDITIONING BOX-TO-FORWARD JUNCTION BOX CABLE ASSEMBLY
REPLACEMENT (Cont).
2.
Install cord connector (25) and sealing ring (24)
on cable assembly (14).
3.
Route wires of cable assembly (14) through hole
in signal conditioning box (22).
4.
Position sealing ring (24) and cord connector (25)
at signal conditioning box (22). install locknut (23)
on cable assembly (14) and tighten locknut.
1.
Install cable assembly (14) through cord connec-
tor (25) and tighten nut (26).
5.
6.
7 .
8.
9 .
10.
11.
install green ground wire (3) on screw (18) with nut (16).
install seven cable assembly wires (2) on terminals of circuit breakers (17) with lockwashers (20) and nuts (19).
Close cover (15) of signal conditioning box (22) and tighten two screws (21).
Install cable assembly (14) through cord connec-
tor (12) and tighten nut (13).
install cord connector (12) and sealing ring (11)
on cable assembly (14).
Route wires of cable assembly (14) through hole
in forward junction box (6).
Position sealing ring (11) and cord connector (12)
at foward junction box (6). Install locknut (10) on
cable assembly (14) and tighten locknut.
4-87