TM 10-5411-203-13
2-4. INSTALLATION AND PREPARATION FOR USE (CONT)
b. Installing Complexing Kit Passageway - Type II, Class A and Class B (ISO Shelter to TEMPER) (Cont)
WARNING
When raising or lowering hinged roof panel and hinged sidewall of ISO
shelter, take care to avoid getting fingers caught. Failure to do so may
result in serious injury.
(e) Raise hinged roof panel (3) to full height using roof support struts (5).
(f)
Rotate roof support struts (5) to upright position. Then lower roof support struts (5) to floor until hinged roof panel
(3) is supported on struts (5).
NOTE
The next procedure requires two persons on the inside and two persons
on the outside of the ISO shelter.
(g) Insert weather barrier (1) through open space between hinged roof panel (3) and and ISO shelter (2).
CAUTION
Avoid excessive stress on fabric when adjusting weather barrier. Failure
to do so may result in fabric damage or separation of seams.
NOTE
When adjusting weather barrier, make sure fabric lays flat without
creases or folds.
(h) Pull weather barrier (1) inside ISO shelter (2) until edge of weather barrier covers top of frame.
(i)
Using two roof support struts (5), lower hinged roof panel (3) onto weather barrier (1) and ISO shelter (2).
(j)
Store roof support struts (5) in stowage brackets.
(k) Latch all inside panel latches to secure hinged roof pane] (3) to ISO shelter (2).
2-31