TM 10-5411-203-132-4. INSTALLATION AND PREPARATION FOR USE (CONT)b.InstallingComplexingKitPassagewav-TypeII,ClassAandClassB(ISOSheltertoTEMPER)(Cont)(12)Place header bar (1) through support straps (2) along roof of connector assembly (3).(13)Connect upright bars (4) to header bar (1) using the following steps:(a)Insert both upright bars (4) into header bar (1).(b)Insert locking pins (5) into holes to secure upright bars (4) to header bar (1).WARNINGThe Complexing Kit Passageway components include two ramps and astairway. The ramps weigh approximately 145 pounds (65.77 kg) and195 pounds (88.45 kg) re- spectively, and the stairs (complete assembly)weigh approximately 70 pounds (31.75 kg). Four persons are required tohandle each of these components. Attempting to lift or carry any one ofthem by yourself could result in serious injury or damage to theequipment.CAUTIONDo not permit ramp or stairway to drop. Support ramp or stairwaythroughout lowering procedure to prevent damage to connectorassembly.(14)For Type II, Class A, place ramp inside Complexing Kit Passageway.2-25