TM 10-5411-200-14
T.O. 35E4-177-1
5-2.
(cont)
8.
Position circuit breaker panel cover (4) against circuit breaker box
(5) and secure by moving four clamp fingers (3) to LOCK position and
tightening four captive screws (2).
Close circuit breaker panel door (1).
INSTALLATION
1.
Position spacer (13) and circuit breaker panel box (5) against
personnel door end endwall panel and secure with screws (10),
lockwashers (11), and washers (12),
2.
Connect wires (9) to light switches and circuit breakers.
(Refer to
paragraph 4-46)
3.
Position panelboard (8) over circuit breakers in circuit breaker box
(5) and secure with four screws (6) and washers (7).
4.
Position circuit breaker panel cover (4) against circuit breaker box
(5) and secure by moving four clamp fingers (3) to lock position and
tightening four captive screws (2).
5.
Close circuit breaker panel door (1.).
5-4