TM 10-5410-221-24
b.
Removal.
circuit breaker. Remove leads (X650C10, X651F10,
X651E10, X661B1, X661A12, X660B12, X660A12) from
GCB1 circuit breaker. Remove leads, (X651C1,
(1) Remove the screws from the terminals
X651D10, X652C10, X652D10, X663A1, X662A12) from
and disconnect electrical leads (X458A16, X452E16,
CB13 circuit breaker.
X451E16, X450E16, X460A16, X459A16) from CB16
circuit breaker (110).
(2) Remove nuts (102) and washers (103)
used to secure circuit breakers (10, fig. 6-22) to panel
(2) Remove nuts (108) and washers (109)
(123).
used to secure circuit breaker (110, fig. 6-22) to panel,
and remove by pulling from rear of panel (123).
c. Installation. Install circuit breakers in reverse
c. Installation. Install circuit breaker in reverse
order of removal using figure 6-22 as a guide referring to
order of removal using figure 6-22 as a guide, referring to
and III for wiring schematic and wiring terminal
identification.
terminal identification.
CB10 Circuit Breaker
CB2 Circuit Breaker
provides protection against damage resulting from an
provides protection against damage resulting for an
overload in the humidifier receptacle. The CB10 circuit
overload in the air-lock light receptacle. The CB2 circuit
breaker open the receptacle on the event the load
breaker (113) opens the receptacle in the event the load
reaches 10 amps. Opening of the circuit breaker is
reaches 5 amps. Opening of the circuit breaker is
indicated by the extension of the reset button. The circuit
indicated by the extension of the reset button. The circuit
breaker is reset by pressing in on the reset button.
breaker is reset by pressing in on the reset button.
b.
Removal.
b.
Removal.
(1) Remove the screws (17) from the
(1) Remove the screws (17) from the
terminals and disconnect electrical lead (X450H12,
terminals and disconnect electrical leads (X452H12,
H488A12, H488B16, H487A12, H486A12, X452K12,
X452G12, X485B12, X485A12) from circuit breaker.
X451H12) from circuit breaker.
(2) Remove nuts (111) and washers (112)
used to secure circuit breaker (113) to panel, and
(2) Remove nuts (105) and washer (106)
remove by pulling from rear of panel (123).
used to secure circuit breaker (107) to panel, and pull
circuit breaker in a straight line from rear of panel (123).
c. Installation. Install circuit breaker in reverse
c. Installation. Install circuit breaker in reverse
order of removal using figure 6-22 as a guide, referring to
order of removal using figure 6-22 as a guide, referring to
and III for wiring schematic and wiring terminal
wiring terminal identification.
identification.
6-35.
CB16 Circuit Breaker
6-37.
CB8 and CB9 Circuit Breakers
a. General. CB16 circuit breaker (116, fig 6-22)
a. General. CB8, and CB9 circuit breakers (116,
provides protection against damage resulting from an
fig. 6-22) provide protection against damage resulting
overload in the sump pump receptacle. The CB16 circuit
from an overload in the surgical light receptacle and the
breaker open the receptacle in the event the load
fluorescent area lights. The CB8 circuit breaker opens
reaches amps.
Opening of the circuit breaker is
indicated by the extension of the reset button. The circuit
breaker is reset by pressing in on the reset button.