TM 10-5410-221-24
Figure 6-29. Remote temperature wiring harness assembly.
(4) Disconnect wires X650E8, X651GE and
(2) Crimp to secure.
X652E8 from terminals 1, 3, and 5 of CB circuit breaker
(101). Disconnect other end of wires from terminals 2, 3,
and 4 on TB2 terminal board (60).
other continuity checking device to check continuity of
(5) Disconnect wire P667A16 from terminal 2
of CB1 circuit breaker (108). Remove other end of wire
fittings on wires.
from terminal 2 of LT1 lamp (79).
f.
Installation.
Install wire and terminal
c. Disassembly. Disassemble wire assemblies
assemblies in reverse order of removal using table 6-2
as required to replace damaged component by removing
as a guide for terminal identification and figure 1-7 for
wiring schematic.
d. Assembly.
Assemble wire assemblies in
6-31.
Distribution Box Assembly
guide and observing the following.
a. General. The distribution box assembly is a
(1) Install terminals (1 through 4).
metal structure used to house the electrical components
6-56