TM 9-4931-374-13&P
3-24. FLUORESCENT LAMP--MAINTENANCE INSTRUCTIONS (cont)
MODIFICATION OF FLUOPESCENT LAMP
NOTE
Steps 1 thru 4 are used only
for initial installation or when
the fluorescent lamp has been
replaced with a new unit.
1
COVER (1).
Remove from fluorescent
lamp (2).
2
SCREW (3). Loosen.
3
TWO WIRES (4). Remove 0.50 in. (1.27
cm) of insulation from ends.
4
FLUORESCENT LAMP (2). Drill four 0.281-in. (0.714-cm)
diameter holes through the back as illustrated.
3-216