TM 9-4931-374-13&P
INSTALLATION
WARNING
1
GREEN WIRE (1), BLACK WIRE (2), AND
Switch S2 in circuit breaker
WHITE WIRE (3). Pull into fluorescent
panel box must be turned to
lamp (4).
OFF position before installing
fluorescent lamp.
2
FLUORESCENT LAMP (4). Position under
two bracket assemblies (5) located under
NOTE
lower shelf (6) of shelving assembly.
The harness assembly has
three wires (green, black, and
white)
which
must
be
connected to the fluorescent
lamp. The fluorescent lamp
has two wires (black and
white).
5 GREEN WIRE (1).
Wrap bare end around
screw (9).
6 SCREW (9). Tighten.
7 TWO BLACK WIRES (10). Twist bare ends
together.
8 TWO WHITE WIRES (11). Twist bare ends
together.
9 TWO CONDUCTOR SPLICES (12). Install on
two black wires (10) and two white wires (11).
3
FOUR SCREWS (7). Install.
4
CONNECTOR (8). Tighten to secure to
fluorescent lamp (4).
3-217