TM 9-4931-374-13&P
3-9. SHOP SET--MAINTENANCE INSTRUCTIONS (cont)
REPAIR/APPLICATION OF STENCILS (cont)
INSTALLATION OF BLIND NUTS
NOTE
The following procedure is to
2
TWO STENCILS (4).
be used only for initial
installation; when the table
a. Wipe surface clean with dry
support has been replaced
cleaning solvent (item 6, app D)
with a new part; or when the
wearing gloves (item 9, app D).
modified table has been
replaced
with
a
new
assembly.
in. (3.81 to 5.08 cm) high as
illustrated.
1
MODIFIED TOOL CABINET (1). Position at cargo door end of left
table (2).
2
BRACE (3). Aline with holes in modified tool cabinet (1).
3
SCREWS (6). Install through brace into front of modified tool cabinet.
4
SCREWS (9). Install through brace into floor.
3-40