TM 9-2330-390-14&P
4-123. AIR CLEANER MAINTENANCE.
This Task Covers:
a. Element Replacement
c. Cleaning and lnspection
b. Removal
Initial Setup:
Equipment Conditions:
Materials/Parts:
Engine starter switch set to OFF position (see
Rags (Item 25, Appendix F)
paragraph 2-20).
Dry cleaning solvent (Item 27, Appendix F)
Tools/Test Equipment:
One element
One gasket
General mechanics tool kit (Item 30, Appendix G)
Compressor unit (Item 4, Appendix G)
General Safety Instructions:
If NBC exposure is suspected, all air filter media must be handled by personnel wearing protective equipment.
Dry cleaning solvent is flammable and must not be used near an open flame. Use only in a well-ventilated area.
Compressed air used for cleaning purposes should never exceed 30 psi (207 kPa).
If NBC exposure is suspected, all engine air cleaner air filter media should be handled
by personnel wearing protective equipment. Consult your NBC Officer or NBC NCO
for appropriate handling or disposal procedures.
4-357