TM 9-2330-390-14&P4-123. AIR CLEANER MAINTENANCE (Con't).1. Remove any accumulated sand or dust fromexterior of cover (3).2.3.Remove wingbolt (6) and cover (3) from body (1).If damaged, remove seal washer (5) and packing(2) from cover (3).4. If damaged, remove label (4) (see para-graph 4-106).5. Remove element (7) from body (1) and discard.Dry cleaning solvent, P-D-660, is toxic and flammable. Always wear protectivegoggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame orexcessive heat. The solvent’s flash point is 100° F-136° F (36° C-59° C). If youbecome dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If solvent contacts eyes, immediately wash your eyes and seek medicalattention.Compressed air used for cleaning or drying purposes, or for clearing restrictions,should never exceed 30 psi (207 kPa). Wear protective clothing (goggles/shield,gloves, etc.) and use caution to avoid injury to personnel.6. Clean body (1), cover (3), and wingbolt (6) with a clean rag. Use a rag dipped in dry cleaning solvent to removestubborn dirt and grease. Dry thoroughly with compressed air.4-358