TM 9-2330-390-14&P
2-34. REDUNDANT POWER OPERATION (Cont).
g. On nonpowered dolly half, remove dust
cap (14) from redundant power quick disconnect
coupler (13) at control valve (12). Connect redundant
power operation hose (4) (both ends have quick discon-
nect nipples) to redundant power quick disconnect
coupler.
NOTE
With redundant power operation, doily halves
cannot be operated simultaneously as with
normal operation.
h. Start engine on powered dolly half (see
paragraph 2-20). Perform required operations, one dolly
half at a time.
i.
Shut down engine on powered dolly half
(see paragraph 2-20).
Disconnect two redundant power kit hoses
(4 and 5). Install protective covers on quick disconnects
and stow hoses.
k.
On nonpowered dolly half, install dust cap
(14) on redundant power quick disconnect coupler (13)
at control valve (12).
i.
On nonpowered dolly half, remove dust
cap (8) from quick disconnect coupler (11) at hydraulic
reservoir (7). Connect quick disconnect nipple (10) to
quick disconnect coupler. install dust cap in dust plug
(9).
2-152