ARMY TM 10–8340-224-13AIR FORCE TO 35E5–6–1NAVY NAVFAC–P–337.A5-15. TEST AND REPAIR LIGHT SET, Type I (CONT).(a) Remove fuse cap and fuse.(b) Remove molded male (1) and female (2) end caps fromluminaire (3).(c) Disconnect lampholder (4) by pressing retainer (5).(d) Pull lens/screen assembly (6) off the extrusionassembly (7) to expose the ballast (8).(e) Separate bracket (9) from male end cap (1).(f) Remove ring terminals (10) from rear of switch (11).(g) Unscrew switch seal (12) and remove switch (11) andpaper insulation (13) from the rear of the bracket(9).(2) Install Switch.(a) Insert new switch (11)into cutout in bracket(b) Screw switch seal (12)(c) Connect ring terminalsthrough paper(9).onto threadedinsulator (13)toggle sleeve.(10) to switch (11).(d) Install bracket (9) into male end cap (1).(e) Slide extrusion assembly (7) into lens/screenassembly (6).(f) Install lampholders (4).(g) Install male (1) and female (2) end caps overluminaire (3).h.Remove and Install Fuse Cap and Fuseholder.(1) Remove Fuseholder.(a) Remove molded male (1) and female (2) end caps fromluminaire (3).(b) Disconnect lampholder (4) by pressing retainer (5).(c) Pull lens/screen assembly (6) off the extrusionassembly (7) to expose the ballast (8).5-24
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business