ARMY TM 10834022413
AIR FORCE TO 35E561
NAVY NAVFACP337.A
(1) Remove Ballast Assembly.
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
WARNING
Lethal voltage is present
connected to power source.
when the light set is
Disconnect from power
source before inspecting or repairing any electrical
component.
Electrical shock and death may result
from failure to heed this warning.
Remove male (1) and female (2) end caps from
luminaire (3).
Disconnect lampholder (4) by depressing retainer
connector (5). Pull lamp (6) out of lens/screen
assembly (7).
Slide the extrusion assembly (8) out of the
lens/screen assembly (7) from male side only.
Disconnect ring terminal (9) of black wire from
switch with flat tip screwdriver.
Disconnect white AC wire (10) by removing splice (11)
and separating wires.
If leads (12,13) from ballast assembly (14) wires are
serviceable,
cut the wires at point of exit from the
ballast assembly (14). If the wires are damaged,
remove from lampholders (4) and extrusion assembly
(8).
Remove two 1/8 hex nuts (15) and washer (16)
securing ballast assembly (14) to extrusion assembly
(8).
Lift ballast assembly (14) off extrusion assembly
(8).
(2) Install Ballast Assembly.
(a) place ballast assembly (14) onto extrusion assembly
(8), and secure with two 1/8 hex nuts (15) and
washers (16).
5-19