ARMY TM 10-8340-224-13
AIR FORCE TO 35E5-6-1
NAVY NAVFAC-P-337.A
5-15. TEST
(b)
( c)
(d)
(e)
(f)
(g)
(h)
e. Remove and Install Female Cable Assembly.
1. Remove Female Cable Assembly.
AND REPAIR LIGHT SET, Type I (CONT).
NOTE
Ensure that one set of wires of
same color from ballast assembly
goes to closest lampholder and one
set goes to far lampholder.
If wire leads (12,13) from ballast assembly (14) were
found serviceable, remove 1/4 of insulation from the
ends of the wires. Solder the wires on the ballast
assembly (14) to wires (12,13) on the extrusion
assembly (8). Apply insulation tape after the solder
point cools.
If wire leads (12,13) from ballast assembly (14) were
removed from the extrusion assembly (8) entirely,
install wires supplied with ballast assembly (14)
onto extrusion assembly (8) and lampholders (4).
Connect AC (white) wire (10) to AC input connection
and install splice (10).
Connect black wire ring terminal (9) to switch.
Ensure that extrusion assembly (8) aligns with track
in lens/screen assembly (7) and ballast assembly (14)
is covered by solid portion.
Slide extrusion
assembly (8) into lens/screen assembly (7).
Install male end cap assembly (1) on luminaire (3).
Install lamp (6).
Install lampholder (4) and female end cap (2) onto
luminaire (3).
5-20