TM 10-7360-208-13&P
Table 3-1. Operator's Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
M2 BURNER UNIT DOES NOT HEAT FOOD SERVICE COMPONENTS PROPERLY.
Step 1.
Check to see if the M2 burner unit flame is on.
Light the M2 burner unit in accordance with TM 10-7360-204-13&P.
Step 2.
Check to see if M2 burner unit flame is green.
Adjust the M2 burner unit in accordance with TM 10-7360-204-13&P.
Step 3.
Check to see if the M2 burner unit flame is the proper height for the desired temperature.
Adjust the M2 burner unit for the temperature desired in accordance with TM 10-7360-
204-13&P.
2.
WATER IN HEATER TANK DOES NOT DRAIN.
Step 1.
Observe water drainage and check for clogged drain.
Remove obstruction from tank-drain or drain hose. Thaw if frozen.
Step 2.
Check for excessive mud at drain hose output.
Relocate drain hose output end.
3.
WORK TABLE IS NOT STURDY.
Step 1.
Check table for proper locking of legs.
Lock properly (para 2-6j).
Step 2.
Check for bent or broken parts.
Notify Unit Maintenance.
3-3