TM 10-5411-224-14TABLE 5-1. DIRECT SUPPORT TROUBLESHOOTING - continuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION5. GROUND JUMPERS NOT SECURED TO DOOR OR SHELTER.Step 1. Check to see if attaching hardware is loose or missing.Tighten hardware or replace ground jumpers as required (paragraph 5-14).6. DOOR ASSEMBLY DOES NOT OPERATE PROPERLY.Step 1. Test door operation (open and close door several times).If door does not operate smoothly, lubricate in accordance with Lubrication Order, Appendix G.Step 2. Inspect door for loose or missing hardware or damaged hinge.Tighten hardware as required.If a hinge is damaged, notify your supervisor.7. DOOR ASSEMBLY DOES NOT SEAL SECURELY.Step 1. Check RFI/EMI gasket for damage.Replace RFI/EMI gasket (paragraph 5-15).Step 2. Check environmental gasket for damage.Replace environmental gasket (paragraph 5-16).If door still does not close tightly, adjust in accordance with Chapter 4, paragraph 4-17.5-3