TM 10-5411-205-133-18.Door Gaskets (cont).(c) Repeat the seal pressure test of paragraph 3-18.b. If the seal pressureremains insufficient, add another 0.032 inch shim.(d) Repeat this process until sufficient seal pressure is developed or until themaximum allowable thickness is obtained.d .Replace. (Figure 3-20) To replace the RFI/EMI gasket (13), remove gasket fromtrack and clean track of any dirt. Place new gasket over track and snap in place. To replacethe silicone weather gasket (14), proceed as follows(1) Remove gasket (14) and clean track from adhesive residue.(2) Apply sealer in track groove all around door and snap new gasket in place intrack on door.CAUTIONAllow at least 30 minutes cure time for adhesive before using door.Figure 3-19. Typical Locations for Door Gasket Testing.3-35
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business