TM 10-5411-203-13
4-26.
BECKET LOOP MAINTENANCE INSTRUCTIONS (TYPE II ONLY) (CONT)
NOTE
Becket loops are made of polyester cord and are used for attaching Type II of the
Complexing Kit Passageway from an ISO shelter to a TEMPER.
Temporary unit level becket loop replacement should be followed by permanent loop
replacement as soon as possible. Refer to Chapter 5 for permanent becket loop
replacement.
Cut becket loop at grommet level.
INSTALL
1.
Cut polyester cord to length.
2.
Fold polyester cord to form loop (1).
3.
Insert one loose end (2) of the loop through the grommet and feed towards the preceding becket loop. Hand-
stitch the fabric and cord end to fix the loop in place.
4.
Insert remaining loose end (3) of the loop through the grommet and feed towards the following becket loop.
Handstitch the fabric and cord end to fix the loop in place.
5.
Using thread, wrap and tie loop as close as possible (4) to its exit from grommet,
NOTE
FOLLOW-ON MAINTENANCE: If required, install Complexing Kit Passageway. (Refer to
para 2-4.)
4-41