TM 10-5411-201-14
T.O. 35E4-178-1
5-3. (cont)
3. Inspect for and replace if necessary:
a. Missing or damaged components.
b. Corrosion or paint damage.
R E P A I R
Repair corrosion or paint damage. (Refer to paragraph 4-44)
ASSEMBLY
1.
2.
3.
4.
5.
Install threaded stud (22), terminal lug (21), three washers (20),
three lockwashers (19), and four nuts (18) in panel (8).
Install binding post body (28), nylon washer (27), two O-rings (26),
nylon washer (25), brass washer (24), lockwasher (17), nut (16), and
rubber cap (15) in panel (8).
Using crimping tool, attach wires to receptacle pins. (Refer to
paragraph 4-47)
Install receptacles (13 and 14) in panel (8) and secure with screws
(9), lockwashers (10), receptacle covers (11), washers (23), and nuts
(12).
Install receptacles (5 and 6) and
with screws (l), lockwashers (2),
INSTALLATION
1.
2.
3.
4.
Position power entry panel
assembly (5) against outside
of personnel door end endwall
panel and secure with rivets
(6). (Refer to paragraph 4-33)
Connect wires to receptacles
and terminals/connectors at
rear of power entry panel
assembly (5). (Refer to
paragraph 4-47)
Position cover assembly against
inside of personnel door end
endwall panel and secure with
screws (l), lockwashers (2),
and washers (3).
Reconnect electrical power to
service entrance receptacle.
gaskets (7) in panel (8) and secure
receptacle covers (3), and nuts (4).
CHANGE 2 5-7