TM 10-5411-201-14
T.O. 35E4-178-1
4-16. (cont)
3.
4.
5.
6.
Position duplex receptacles (28) in outlet boxes (32) and secure by
tightening captive screws (31).
Attach duplex covers (30) to duplex receptacles (28) with screws (29).
Connect wires from fixed sidewall duplex receptacles (28) in conduit
outlet body (12).
(Refer to paragraph 4-47. )
Position conduit outlet cover (11) on conduit outlet body (12) and
secure by tightening two captive screws (10).
Roof Beam Wiring
1.
Position roof beam (9) against roof and install washers (27),
lockwashers (26), and bolts (25).
2.
Install push bar assembly pins (24) at each of
assemblies.
3.
Connect conduit locknut (23) at roof beam area
and conduit outlet body (12).
4.
Connect conduit locknut (22) at roof beam area
and top of circuit breaker box (5).
4-54
CHANGE 2
three push bar
between roof beam (9)
between roof beam (9)