TM 10-5411-201-14T.O. 35E4-178-14-13.(cont)7.Remove wirereceptaclesnuts (13) and disconnect wires from rear of duplex(11).NOTETag wires for reconnection.8.Disconnect connectors (14 and 15) and separate conduit (6, 7, and16) from outlet boxes (12).9.RemoveDISASSEMBLYscrews (17) and outlet boxes (12) from fixed sidewall.1.Removeduplex2.Loosenscrews (1) andcovers (2).captive screws (3)and move duplex receptacles(4) away from junction boxes(5) as far as they will go.3.Remove wire nuts (8) andterminals, and disconnectwires from rear of receptacles(4), where applicable,NOTETag wires for reconnection4.Remove liquid tight connectors (6) from junction boxes (5) andseparate connectors from electrical cords (7).5.Remove captive screws (9) from junction boxes (5).CLEANING, INSPECTION1.Clean cable and receptacle assembly and component surfaces.2.Inspect mounting surfaces for corrosion and damage.3.Inspect for and replace if necessary:a.Missing or damaged components.b.Corrosion or paint damage.4-39