TM 10-5411-201-14
T.O. 35E4-178-1
4-11. (cont)
C A U T I O N
When removing end caps, hold safety tube level to
prevent fluorescent tube from accidentally sliding
out and dropping.
6.
Assemble light shields (5) on fluorescent lamps (4) and install in
light frame (6) by sliding in and rotating.
7.
Install split retaining rings (3) on end of fluorescent lamps (4).
8.
Attach cover (2) to light frame (6) with screws (l).
NOTE
Replace hinged roof area ceiling light in
accordance with paragraph 3-5. Place all circuit
breakers to the ON position.
4-12.
FIXED ROOF AREA CEILING LIGHT TESTING, REPLACEMENT, AND REPAIR
This task covers:
Testing
e.
Repair
b.
Remova1
f. Assembly
Disassembly
g.
Installation
d.
Cleaning, Inspection
a.
c.
INITIAL SETUP
Special Tools
Personnel
Hand blind riveter, Appendix B, Item 2
Electrician
Test Equipment
Equipment Condition
Multimeter, Appendix B, Item 4
All circuit breakers and
Standard Tools
switches in OFF position
General mechanics tool kit
TESTING
1.
2.
Remove three screws (1) and
cover (2).
Using multimeter, check for
continuity of fluorescent
lamps, ballast, and wiring.
CHANGE 2
4-31