TM 10-5411-201-14T.O. 35E4-178-14-11. (cont)6.Remove installation screw (9) attaching terminal lug (10) on thirdwire from electrical cord (8).7.Remove locknut (13) and remove electrical cord (8) with liquid tightconnector (11) and plug (12) from light frame (6).8.Remove nuts (14) and remove ballast (15) from light frame (6).9.Drill out rivets (16) and remove two light support plates (17) fromlight frame (6).(Refer to paragraph 4-33. )CLEANING, INSPECTION1.Clean hinged roof area ceiling light and component surfaces.NOTEDo not use water to clean hinged roof area ceiling lights.2.Inspect mounting surfaces for corrosion and damage.3.Inspect for and replace if necessary:a.Missing or damaged components.b. Corrosion or paint damage.REPAIRRepair corrosion or paint damage. (Refer to paragraph 4-44)ASSEMBLY1.Position two light support plates (17) on light frame (6) and installrivets (16).(Refer to paragraph 4-33)CHANGE 24-29
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business