TM 10-5411-200-14
T.O. 35E4-177-1
4-8.
(cont)
8.
Disconnect wires from terminals/connectors at rear of panel (5).
NOTE
Tag all wires for reconnection.
9.
Remove rubber cap (21), nut (22), lockwasher (23), brass washer
(29), nylon washer (30), two O-rings (31), nylon washer (32), and
binding post body (33) from panel (5).
10.
Remove four nuts (24), three lockwashers (25), three washers (26),
terminal lug (27), and threaded stud (28) from panel (5).
CLEANING, INSPECTION
1.
Clean power entry panel and component surfaces.
2.
Inspect mounting surfaces for corrosion and damage.
3.
Inspect for damaged receptacles, binding posts, terminals, or
threaded stud.
Replace damaged receptacles, binding post, terminals, or threaded stud.
Terminals/Connectors
1.
Install threaded stud (28), terminal lug (27), three washers (26),
three lockwashers (25), and four nuts (24) in panel (5).
2.
Install binding post body (33), nylon washer (32), two O-rings (31),
nylon washer (30), brass washer (29), lockwasher (23), nut (22), and
rubber cap (21) In panel (5).
3.
Connect all wires to terminals/connectors at rear of panel (5).
(Refer to paragraph 4-46)
4.
Inside shelter, position cover assembly (4) against personnel door
end endwall panel and secure with washers (3), lockwashers (2), and
screws (1).
4-16