4-8.
(cont)
Receptacles
5.
Install
receptacles
(17 and 18), nuts (16), washers (19), receptacle
covers (15),
lockwashers
(14), and screws (13) in panel (5).
6.
Install gaskets (12),
receptacles
(10 and 11), nuts (9), receptacle
covers (8), lockwashers (7), and screws (6) in panel (5).
7.
Connect all wires (20) to receptacles (10, 11, 17, and 18).
(Refer
to 4-46.)
8. Inside shelter, position
cover assembly
(4) against personnel door
end endwall panel and secure with washers (3),
lockwashers
(2), and
screws (1).