TM 10-5411-200-14T.O. 35E4-177-14-12. (cont)6. Remove nuts (17) and remove ballast (16) from light frame (3).7. Drill out rivets (18) and remove two light support plates (19) fromlight frame (3).(Refer to paragraph 4-32)CLEANING,INSPECTION1. Clean hinged roof area ceiling light and component surfaces.2.Inspect mounting surfaces for corrosion and damage.3.Inspect for and replace if necessary:a.Missing or damaged components.b. Corrosion or paint damage.REPAIRRepair corrosion or paint damage. (Refer to paragraph 4-43)ASSEMBLY1.Position two light support plates (19) on light frame (3) andinstall rivets (18).(Refer to paragraph 4-32)2. Position ballast (16) in light frame (3) and secure with nuts (17).3. Connect two wires from ballast (16) to contacts on light frame (3)as follows:Yellow to YellowYellow to Black4. Connect four wireslight frame (3) asRed to BlackRed to BlackBlue to WhiteBlue to Whitefrom ballast (16) to contacts at opposite end offollows:CHANGE 24-35