TM 10-5411-200-14
T.O. 35E4-177-1
4-12. (cont)
NOTE
Tag wires for reconnection.
2.
Remove wire nuts (9), separate conduit wiring.
3.
Remove installation screw (11) attaching terminal lug (12) on third
wire (5) from conduit (4).
4.
Loosen locknut (10), and separate conduit (4) and its wiring from
fixed roof area ceiling light.
5. Remove four screws (6), lockwashers (7), and washers (8), and remove
fixed roof area ceiling light (3) from fixed roof.
WARNING
In the event of lamp breakage, care must be taken
in the removal of broken glass fragments and white
phosphorus dust that may be dispersed within the
fixture.
Inhalation of phosphorus dust could cause
serious injury.
DISASSEMBLY
1.
Remove screws (1) and cover (2) from light frame (3).
CHANGE 2
4-33