TM 10-5410-284-13&PTM 10602A-13&PLIGHTWEIGHT MAINTENANCE ENCLOSURE (LME) 0027 00POWER DISTRIBUTION BOX0027 00-5RemoveRemove pan head screws (1) and lock nuts (2) securing receptacle (3) to panel and retain nuts.Lift receptacle off panel.Loosen flathead screws (4).Remove thewires. (Tagthe wires)InstallPlace new receptacle (3) on panel.Tighten pan head screws (1) and lock nuts (2) to secure receptacle to panel.Re-attach tagged wires with flathead screws (4).To Replace defective GFCI receptacle: