Remove
Loosen flathead screws securing wires to terminal block, and remove wires. (Tag the wires)
Remove truss head screws (1)and lock nuts (2) securing PDB terminal block assembly (3) to component
panel.
Separate terminal block from terminal plate by removing 2 hex socket screws (4) and lock nuts (5).
Retain screws.
Install
Install new terminal block onto terminal plate with 2 hex socket screws (4) and lock nuts (5).
Install terminal block assembly (3) onto component panel using the 2 retained truss head screws (1) and
lock nuts (2).
Re-install tagged wires onto terminal block and secure with flathead screws.
To replace a defective power distribution block assembly, proceed as follows: