TM 10-5410-229-13&PSection V. UNIT TROUBLESHOOTING4-9. GENERAL.Table 4-2 lists common malfunctions of the equipment and contains instructions for unit personneldiagnosing and correcting each malfunction. Perform the indicated steps in the order listed.NOTEThis manual cannot list all malfunctions that may occur. If a malfunctionis either not listed or cannot be corrected by the prescribed procedure,notify your supervisor.Table 4-2. Unit TroubleshootingMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1.FRAME ASSEMBLIES WILL NOT FIT TOGETHER.Check for missing or bent frame components. Inspect for damaged fittings.Replace any bent or missing frame components as described inparagraph 4-14.2.TENT LEAKINGa. Check to make sure that windows are sealed, the stove pipe opening is closed, and all hook andpile fasteners are secured.b. Check for rips, tears, holes or separating seams in the roof cap or wall fabric assemblies.Repair any rips, tears, or holes not exceeding 6 " in length asdescribed in paragraph 4-12. Refer more extensive damage todirect support maintenance for repair.4-8