3-38. CABLE ADAPTER ASSEMBLY-- MAINTENANCE INSTRUCTIONS (cont)
PREPARATION OF CABLE FOR PLUG CONNECTOR
NOTE
The following procedure is used only for initial assembly
or when the cable, insulation, or compression connector
has been replaced with a new item.
1
CABLE (1).
a. Cut ends square.
b. Remove 3 in. (7.62 cm) of jacket (2) from end.
2
FOUR GREEN WIRES (3).
a. Remove 1.50 in. (3..81 cm) of insulation.
b. Twist exposed end of wire.
3
WHITE WIRE (4).
a. Remove 1.50 in. (3.81 cm) of insulation.
b. Twist exposed end of wire.