TM 9-4931-374-13&P
NOTE
Insulation
(34)
and
compression connector (35)
are to be removed from cable
(3) only if replacement is
required.
22
INSULATION (34).
Remove from cable
(3) by cutting.
20
TWO CABLE SEAL BUSHINGS (33).
Remove from cable (3).
21
CLAMPING NUT (21).
Remove from
cable (3).
REPAIR
1
FEMALE CONNECTOR (1).
a. Replace with
a
new
item
if
not
repairable.
b. Refer to page 3-310, paragraph 3-39, for
repair procedures.
2
PLUG CONNECTOR (2). Replace if any
part is damaged.
23
COMPRESSION CONNECTOR
(35).
Remove from cable (3) by cutting.
3-295