TM 9-4931-374-13&P
3-38. CABLE ADAPTER ASSEMBLY--MAINTENANCE INSTRUCTIONS (cont).
REMOVAL (cont)
1
PLUG CONNECTOR (1).
Disconnect
from mating connector (2) of power
distribution panel.
2
TERMINAL LUG (3). Loosen screw (4).
3
GROUNDING ROD WIRE (5).
Remove
from terminal lug (3).
4
SCREW (6). Remove from electrical plug
connector (male) (7) on 120/208V cable
assembly.
CAUTION
Install
dust
covers
on
connectors immediately after
disconnection
to
protect
against dirt, dust, etc.
7
FEMALE CONNECTOR (9). Disconnect
from electrical plug connector (male) (7)
on 120/ 208V cable assembly.
5
CABLE ASSEMBLY (8).
Free one end
from screw (6).
6
SCREW (6). Replace on electrical plug
connector (male) (7).
3-290