ARMY TM 10-8340-224-13
AIR FORCE TO 35E5-6-1
NAVY NAVFAC-P-337.A
2-25. DECALS AND INSTRUCTION PLATES (CONT) .
STEP-16
INSTALL ONE OF THE SINGLE PLY TENT FLOOR SECTIONS BY ALIGNING
NOTCHES WITH FRAME MEMBERS THEN SECURING TIE TAPES TO FRAME.
ADDITIONAL FLOOR SECTIONS ARE INSTALLED BY MATING THE HOOK AND
PILE FASTENERS ALONG EDGE OF FLOOR THEN SECURING TIE TAPES TO
FRAME .
STEP-17
INSULATED FLOOR PANELS ARE INSTALLED BY PLACING THEM OVER THE
SINGLE PLY FLOOR SECTIONS AND LOCKING TOGETHER BY MATING HOOK AND
PILE FASTENERS ALONG EDGE OF FLOOR SECTIONS.
ELECTRICAL DISTRIBUTION SYSTEM
NOTE: AN ELECTRICAL DISTRIBUTION SYSTEM IS AVAILABLE FOR USE WITH
THIS TENT. THE ABOVE ILLUSTRATION DEPICTS LOCATION OF THE
DISTRIBUTION BOX, LAMPS AND CONVENIENCE OUTLETS.
INCANDESCENT LAMPS
A LAMP CABLE ASSEMBLY IS AVAILABLE WHICH CONTAINS MOLDED SOCKETS
FOR TWO INCANDESCENT LIGHT BULBS. THESE ASSEMBLIES CAN BE
SUBSTITUTED FOR THE FLUORESCENT LIGHTS WHEN LOW LEVEL LIGHTING IS
ADEQUATE.
FLUORESCENT LAMPS
FOUR LUMINAIRES COME PACKED IN A FIBERGLASS CARRYING CONTAINER.
EACH LUMINAIRE IS FURNISHED WITH A LIGHT SUPPORT STRAP WITH FOUR
ATTACHED SUPPORT STRAPS. THE LIGHT SUPPORT STRAPS FASTEN OVER THE
FRAME HEADER ASSEMBLY. THE LUMINAIRES ARE SUSPENDED FROM THE
LIGHT SUPPORT STRAP BY MEANS OF THE 2 SUPPORT STRAPS. WHEN THE
LINER IS INSTALLED, THE 2 STRAPS ARE PASSED THRU THE SLITS IN THE
LINER AND THEN ATTACHED TO THE LUMINAIRES.
Figure 25.
ABBREVIATED SET UP INSTRUCTIONS (CONT)
2-66