TM 10-7360-208-13&P
Table 4-2. Unit Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
HEATER TANK ASSEMBLY HANDLES OR CATCHES MALFUNCTION.
Check to see if the handle or catches are bent or broken.
If bent or broken, replace the catch or handle as described in paragraph 4-15.
6.
MOUNTED CAN OPENER DOES NOT CUT.
Check for dull blades.
Replace blades per paragraph 4-16.
7.
LIQUID DISPENSER LEAKS OR DOES NOT KEEP BEVERAGE AT PROPER TEMPERATURE.
Check and inspect the latch assembly, lid gasket, lid assembly, vent assemblies, and faucet
assemblies.
Replace faulty items as described in paragraph 4-18.
8.
FOOD CONTAINER DOES NOT KEEP FOOD AT PROPER TEMPERATURE.
Check and inspect the hinge assembly, gasket and latch assembly.
Replace defective items as described in paragraph 4-19.
9
STORAGE CABINET DOOR DOES NOT OPEN OR CLOSE PROPERLY.
Check for obstruction, warped door, damaged catch and hook
Notify direct support maintenance.
10.
STORAGE CABINET HANDLE IS LOOSE.
Check handle mounting hardware.
Notify direct support maintenance.
4-5