TM 10-7360-208-13&PTable 2-2. Operator’s Preventive Maintenance Checks and ServicesB-Before Operation D-During OperationA-After OperationBDA7Heater TankInspect heater tank assembly forHeater cabinet isAssemblybroken, loose or missing hardware,physically damaged orbent members, broken welds andleaks. Water drainleaking drain valve. Check thatvalve leaks. Warningwarning and instruction plates areplate missing orproperly mounted and legible.illegible.8Cooking PotInspect the cooking pot cradleCradleassembly for bent members, orAssemblybroken welds. Check that warningplate is properly mounted andlegible. Refer to item 5 for racks.9M2 Burner UnitPerform PMCS IAW TM 10-7360-204-13&P.10Mounted CanCheck mounted can opener forOpeneroperation, damage, and dull blades.11Work TableCheck to ensure tables are level andsecure. Check for broken welds,loose or missing hardware.12LiquidInspect liquid dispenser for damageDispenseror missing hardware. Check for leaks.Inspect operation of faucet assembly,spout assembly, cap vent and lidassembly. Insure gasket on lidassembly forms a good seal.13FoodCheck for damage to gasket, latchesContainerand hinges. Check door for properclosing.14StorageInspect for dents, holes and brokenCabinetwelds or damaged frame. Inspectrecessed doors for proper opening andclosing. Check handles for firmness.Check that catch holds door firmly.2-5INTERVALITEMNO.Item To BeInspectedEquipment NotReady/Available If:Procedures