TM 10-7310-281-13&PMODERN BURNER UNIT (MBU)0003 00THEORY OF OPERATION0003 00-4BATTERYPACKVEHICLE28 VdcBATTERY PACKMBUUNIT #1Power Cable, 25ftMBUUNIT #2NATO Adapter CableMBUUNIT #3(KCLFF-E)PowerCable, 25ftCable,2 BranchPrimary MBU power configuration for 24V DCpower source used with the Kitchen, CompanyLevel, Field Feeding (KCLFF). Power is drawnfrom the vehicle using the NATO adapter/cableand connected to the battery pack. From thebattery pack, power is distributed using a 25 foot(24Vdc) power cable extension connected to abranch cable which in turn is connected to theburner. Up to 3 MBUs can be operated at onetime.Alternate MBU power configuration for 24 V DCpower source used with the KCLFF showspower drawn from the vehicle using the NATOadapter cable and connected directly to one ormore burners using a 25 foot (24Vdc) powercable extension (as necessary), connected to abranch cable which in turn is connected toburner(s) This configuration can be used if noneed to employ the battery module is foreseen.A second alternate configuration shows the useof the battery pack only. When this powersource is used, it is directly connected to thedesignated burners using a 25 ft (24V DC)extension (if necessary), or directly to the branchcable.Figure 1-5 MBU Power Configuration for Vehicular or Battery Supplied 24V DC PowerEND OF WORK PACKAGE