TM 10-7310-281-13&P
MODERN BURNER UNIT (MBU)
0003 00
THEORY OF OPERATION
0003 00-4
BATTERY
PACK
VEHICLE
28 Vdc
BATTERY PACK
MBU
UNIT #1
Power Cable, 25ft
MBU
UNIT #2
NATO Adapter Cable
MBU
UNIT #3
(KCLFF-E)
Power
Cable, 25ft
Cable,
2 Branch
Primary MBU power configuration for 24V DC
power source used with the Kitchen, Company
Level, Field Feeding (KCLFF). Power is drawn
from the vehicle using the NATO adapter/cable
and connected to the battery pack. From the
battery pack, power is distributed using a 25 foot
(24Vdc) power cable extension connected to a
branch cable which in turn is connected to the
burner. Up to 3 MBUs can be operated at one
time.
Alternate MBU power configuration for 24 V DC
power source used with the KCLFF shows
power drawn from the vehicle using the NATO
adapter cable and connected directly to one or
more burners using a 25 foot (24Vdc) power
cable extension (as necessary), connected to a
branch cable which in turn is connected to
burner(s) This configuration can be used if no
need to employ the battery module is foreseen.
A second alternate configuration shows the use
of the battery pack only. When this power
source is used, it is directly connected to the
designated burners using a 25 ft (24V DC)
extension (if necessary), or directly to the branch
cable.
Figure 1-5 MBU Power Configuration for Vehicular or Battery Supplied 24V DC Power