TM 10-7310-281-13&P
MODERN BURNER UNIT (MBU)
0002 00
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS
0002 00-5
EQUIPMENT DATA
The following technical and identification data pertains to the MBU and selected support equipment.
Table 1-1 Equipment Data
WEIGHT:
Fully fueled ................................ ................................ ................................ ....................... 58 lbs. (26 Kg)
Without fuel................................ ................................ ................................ .................... 41.5 lbs. (19 Kg)
DIMENSIONS:
Height ................................ ................................ ................................ .............................. 9.75 in (25 cm)
Depth ................................ ................................ ................................ ................................ ...23 in (58 cm)
Width................................ ................................ ................................ ................................ ....19 in (48 cm)
FUEL CAPACITY (Usable) ................................ ................................ ................................ ........2 US gal (7.6 lt)
INPUT CONNECTORS:
Power-in receptacle................................ ................................ ................................ . MS3102E-16-11P
Fuel................................ ................................ ................... Parker Double Shut-off Coupling, BH2-60Y
FUEL CONSUMPTION:
Rate of fuel consumption:
Operating at maximum firing rate:................................ ................................ . 2.8 lbs. (1.27 Kg)/hr
Operating at minimum firing rate:................................ ................................ .....1.2 lbs. (.54 Kg)/hr
MBU operation (full fuel tank) ................................ ................................ ................................ up to 4 hrs
OUTPUTS:
Heat (setting dependent) ................................ ................................ ............... 18,000 to 60,000 BTU/hr
Carbon monoxide (setting dependent) ................................ ................................ ......... 50 to 120 ppm
FUEL REQUIREMENTS ................................ ................................ ................................ .............................. JP-8
ELECTRICAL REQUIREMENTS ................................ ................................ ................... $22 and # 29.5 V DC
ENVIRONMENTAL:
Operating temperatures................................ ................................ . -250F to +1250F (-320C to +520C)
Operating elevations to 10,000 ft above sea level
POWER CONVERTER
Capacity. ................................ ............................ 600 Watts continuous, 1000 Watts for 1 Min. at 26 V DC
Input Voltage Range................................. ................................ ................................ .............. 90 to 132 V AC
Input Frequency................................. ................................ ................................ .............................. 47 to 63 Hz
BATTERY PACK
Battery Type. ................................ .................. 2 Sealed Lead Acid Batteries, Genesis 0766-2003B0N01
Input Voltage Range................................. ................................ ................................ ............. 22 to 29.5 V DC
CONNECTORS (24V DC CABLE)................................. ................................ .......... MS 3106F16-11S, 11682338
ADAPTER (FUEL)................................. ................................ ................................ ............... NSN 7240-21-912-7125
FUEL LINE CONNECTOR ADAPTER
.BH2-61Y, BH2-60Y