TM 10-7310-281-13&PMODERN BURNER UNIT (MBU)0004 00CONTROLS AND INDICATORS0004 00-1GENERALThe following illustrations and tables show the location and list the function of each control and indicator on theMBU, power converter, and battery pack.MBUTable 2-1 describes the controls and indicators for the MBU.Table 2-1 MBU Controls and IndicatorsKEYCONTROL AND INDICATORFUNCTION1STARTBurner start-up2STOPBurner shut-down3FuelStarts fueling function4PowerMain power on/off button5Firing Rate Adjustment (HIGH (Start) LOW)Adjusts burner firing rate6RunIndicates burner is operating7Warm UpIndicates burner is warming up8Fueling/FuelIndicates tank is filling (during fueling) or full9Low FuelIndicates low fuel shut-down sequence active10VoltageIndicates incorrect voltage11ServiceIndicates mechanical malfunction12TOTAL HOURSShows accumulated hours of operation. Background lightindicates power-on condition.234578910111261