TM 10-7310-281-13&P
MODERN BURNER UNIT (MBU)
0004 00
CONTROLS AND INDICATORS
0004 00-1
GENERAL
The following illustrations and tables show the location and list the function of each control and indicator on the
MBU, power converter, and battery pack.
MBU
Table 2-1 describes the controls and indicators for the MBU.
Table 2-1 MBU Controls and Indicators
KEY
CONTROL AND INDICATOR
FUNCTION
1
START
Burner start-up
2
STOP
Burner shut-down
3
Fuel
Starts fueling function
4
Power
Main power on/off button
5
Firing Rate Adjustment (HIGH (Start) LOW)
Adjusts burner firing rate
6
Run
Indicates burner is operating
7
Warm Up
Indicates burner is warming up
8
Fueling/Fuel
Indicates tank is filling (during fueling) or full
9
Low Fuel
Indicates low fuel shut-down sequence active
10
Voltage
Indicates incorrect voltage
11
Service
Indicates mechanical malfunction
12
TOTAL HOURS
Shows accumulated hours of operation. Background light
indicates power-on condition.
2
3
4
5
7
8
9
10
11
12
6
1